Features
      ・ The hanging load and the operating radius are displayed and the alarm is output.
・ Japan Crane Association accepted product
Specification
| Specification name | Specification contents | 
|---|---|
| Power supply voltage to sensor | Load Cell 12 VDC±1.2 VDC / within 40 mA/unit Angle detector 12 VDC±1.2 VDC / within 20 mA  | 
            
| Applicable transducer | Load Cell Strain gage transducers(350 Ω)3 points(load cell 1~3) Angle detector WR-7UHA112-V-1(MIDORI PRECISIONS)  | 
            
| Input range | Load cell F.S. setting can be made at the input from 0.5 mV/V to 3 mV/V Angle detector 1.40 V ~ 5.32 V  | 
            
| Display of moment ratio | Display range from 60 % to 125 % (Bar graph LED) Minimum resolution 2.5 %  | 
            
| Present load display | Display range from -99 t to 999 t or from -9.9 t to 199.9 t | 
| Present working radius | Display range from 0.0 m to 99.9 m | 
| Condition display | Applied load cell is specified. (Load cell No.1 ~ 3) | 
| Monitor display | One of the selection has been displayed either of Limit load, Limit radius, Jib angle, Moment No., Jib No. or Range No. | 
| Limited output monitor display | Display output condition of limited output No.1 to No.6 | 
| Display of 90 % and 100 % | Display signal output condition of 90 % and 100 % of the lifting load | 
| Display of up and down | Display input signal condtion for correction executing instruction of lift-up and lift-down | 
| Display times | Changeable to 1 times/s, 2 times/s or 0.5 times/s | 
| Buzer for emergency | EB2112(Panasonic Corporation) or DSEB2112(Devices Sales Technology Co.,Ltd.) | 
| Power supply voltage | 24 VDC (18 VDC ~36 VDC), Power consumption Approx. 3 A | 
| Outline dimensions (W×H×D) | 100 mm x 210 mm x 162.9 mm (Excluding protruding parts) | 
| Weight | Approx. 2.1 kg | 